| 3VA2110-5HL32-0CL0 | Siemens | circuit breaker 3VA2 IEC frame 160 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU320, LI, In=100A overload protection Ir=40A...100A short-circuit protection Ii=1.5...12 x In nut keeper kit undervoltage release (UVR) 120-127V AC 50/ |  | 
											
						
							| 3VA2110-5HL32-0DA0 | Siemens | circuit breaker 3VA2 IEC frame 160 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU320, LI, In=100A overload protection Ir=40A...100A short-circuit protection Ii=1.5...12 x In nut keeper kit undervoltage release (UVR) 208-230V AC 50/ |  | 
											
						
							| 3VA2110-5HL32-0DC0 | Siemens | circuit breaker 3VA2 IEC frame 160 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU320, LI, In=100A overload protection Ir=40A...100A short-circuit protection Ii=1.5...12 x In nut keeper kit undervoltage release (UVR) 208-230V AC 50/ |  | 
											
						
							| 3VA2110-5HL32-0DH0 | Siemens | circuit breaker 3VA2 IEC frame 160 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU320, LI, In=100A overload protection Ir=40A...100A short-circuit protection Ii=1.5...12 x In nut keeper kit undervoltage release (UVR) 208-230V AC 50/ |  | 
											
						
							| 3VA2110-5HL32-0DL0 | Siemens | circuit breaker 3VA2 IEC frame 160 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU320, LI, In=100A overload protection Ir=40A...100A short-circuit protection Ii=1.5...12 x In nut keeper kit undervoltage release (UVR) 208-230V AC 50/ |  | 
											
						
							| 3VA2110-5HL32-0HA0 | Siemens | circuit breaker 3VA2 IEC frame 160 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU320, LI, In=100A overload protection Ir=40A...100A short-circuit protection Ii=1.5...12 x In nut keeper kit shunt trip (STL) 12-30V DC, 24V AC 50/60Hz |  | 
											
						
							| 3VA2110-5HL32-0HC0 | Siemens | circuit breaker 3VA2 IEC frame 160 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU320, LI, In=100A overload protection Ir=40A...100A short-circuit protection Ii=1.5...12 x In nut keeper kit shunt trip (STL) 12-30V DC, 24V AC 50/60Hz |  | 
											
						
							| 3VA2110-5HL32-0HH0 | Siemens | circuit breaker 3VA2 IEC frame 160 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU320, LI, In=100A overload protection Ir=40A...100A short-circuit protection Ii=1.5...12 x In nut keeper kit shunt trip (STL) 12-30V DC, 24V AC 50/60Hz |  | 
											
						
							| 3VA2110-5HL32-0HL0 | Siemens | circuit breaker 3VA2 IEC frame 160 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU320, LI, In=100A overload protection Ir=40A...100A short-circuit protection Ii=1.5...12 x In nut keeper kit shunt trip (STL) 12-30V DC, 24V AC 50/60Hz |  | 
											
						
							| 3VA2110-5HL32-0JA0 | Siemens | circuit breaker 3VA2 IEC frame 160 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU320, LI, In=100A overload protection Ir=40A...100A short-circuit protection Ii=1.5...12 x In nut keeper kit shunt trip (STL) 110-127V DC, AC 50/60Hz |  | 
											
						
							| 3VA2110-5HL32-0JC0 | Siemens | circuit breaker 3VA2 IEC frame 160 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU320, LI, In=100A overload protection Ir=40A...100A short-circuit protection Ii=1.5...12 x In nut keeper kit shunt trip (STL) 110-127V DC, AC 50/60Hz 2 |  | 
											
						
							| 3VA2110-5HL32-0JH0 | Siemens | circuit breaker 3VA2 IEC frame 160 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU320, LI, In=100A overload protection Ir=40A...100A short-circuit protection Ii=1.5...12 x In nut keeper kit shunt trip (STL) 110-127V DC, AC 50/60Hz 2 |  | 
											
						
							| 3VA2110-5HL32-0JL0 | Siemens | circuit breaker 3VA2 IEC frame 160 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU320, LI, In=100A overload protection Ir=40A...100A short-circuit protection Ii=1.5...12 x In nut keeper kit shunt trip (STL) 110-127V DC, AC 50/60Hz 2 |  | 
											
						
							| 3VA2110-5HL32-0KA0 | Siemens | circuit breaker 3VA2 IEC frame 160 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU320, LI, In=100A overload protection Ir=40A...100A short-circuit protection Ii=1.5...12 x In nut keeper kit shunt trip (STL) 220-250V DC, 208-277V AC |  | 
											
						
							| 3VA2110-5HL32-0KC0 | Siemens | circuit breaker 3VA2 IEC frame 160 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU320, LI, In=100A overload protection Ir=40A...100A short-circuit protection Ii=1.5...12 x In nut keeper kit shunt trip (STL) 220-250V DC, 208-277V AC |  | 
											
						
							| 3VA2110-5HL32-0KH0 | Siemens | circuit breaker 3VA2 IEC frame 160 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU320, LI, In=100A overload protection Ir=40A...100A short-circuit protection Ii=1.5...12 x In nut keeper kit shunt trip (STL) 220-250V DC, 208-277V AC |  | 
											
						
							| 3VA2110-5HL32-0KL0 | Siemens | circuit breaker 3VA2 IEC frame 160 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU320, LI, In=100A overload protection Ir=40A...100A short-circuit protection Ii=1.5...12 x In nut keeper kit shunt trip (STL) 220-250V DC, 208-277V AC |  | 
											
						
							| 3VA2110-5HL36-0AA0 | Siemens | circuit breaker 3VA2 IEC frame 160 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU320, LI, In=100A overload protection Ir=40A...100A short-circuit protection Ii=1.5...12 x In clamp connection |  | 
											
						
							| 3VA2110-5HL36-0AB0 | Siemens | circuit breaker 3VA2 IEC frame 160 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU320, LI, In=100A overload protection Ir=40A...100A short-circuit protection Ii=1.5...12 x In clamp connection 2 auxiliary switches HP |  | 
											
						
							| 3VA2110-5HL36-0AC0 | Siemens | circuit breaker 3VA2 IEC frame 160 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU320, LI, In=100A overload protection Ir=40A...100A short-circuit protection Ii=1.5...12 x In clamp connection 2 auxiliary switches HQ |  | 
											
						
							| 3VA2110-5HL36-0AD0 | Siemens | circuit breaker 3VA2 IEC frame 160 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU320, LI, In=100A overload protection Ir=40A...100A short-circuit protection Ii=1.5...12 x In clamp connection 3 auxiliary switches HQ |  | 
											
						
							| 3VA2110-5HL36-0AE0 | Siemens | circuit breaker 3VA2 IEC frame 160 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU320, LI, In=100A overload protection Ir=40A...100A short-circuit protection Ii=1.5...12 x In clamp connection 4 auxiliary switches HQ |  | 
											
						
							| 3VA2110-5HL36-0AF0 | Siemens | circuit breaker 3VA2 IEC frame 160 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU320, LI, In=100A overload protection Ir=40A...100A short-circuit protection Ii=1.5...12 x In clamp connection 1 auxiliary switch HQ 1 trip alarm switc |  | 
											
						
							| 3VA2110-5HL36-0AG0 | Siemens | circuit breaker 3VA2 IEC frame 160 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU320, LI, In=100A overload protection Ir=40A...100A short-circuit protection Ii=1.5...12 x In clamp connection 1 auxiliary switch HP 1 trip alarm switc |  | 
											
						
							| 3VA2110-5HL36-0AH0 | Siemens | circuit breaker 3VA2 IEC frame 160 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU320, LI, In=100A overload protection Ir=40A...100A short-circuit protection Ii=1.5...12 x In clamp connection 2 auxiliary switches HQ 1 trip alarm swi |  | 
											
						
							| 3VA2110-5HL36-0AJ0 | Siemens | circuit breaker 3VA2 IEC frame 160 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU320, LI, In=100A overload protection Ir=40A...100A short-circuit protection Ii=1.5...12 x In clamp connection 2 auxiliary switches HP 1 trip alarm swi |  | 
											
						
							| 3VA2110-5HL36-0BA0 | Siemens | circuit breaker 3VA2 IEC frame 160 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU320, LI, In=100A overload protection Ir=40A...100A short-circuit protection Ii=1.5...12 x In clamp connection undervoltage release (UVR) 24V DC |  | 
											
						
							| 3VA2110-5HL36-0BC0 | Siemens | circuit breaker 3VA2 IEC frame 160 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU320, LI, In=100A overload protection Ir=40A...100A short-circuit protection Ii=1.5...12 x In clamp connection undervoltage release (UVR) 24V DC 2 auxi |  | 
											
						
							| 3VA2110-5HL36-0BH0 | Siemens | circuit breaker 3VA2 IEC frame 160 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU320, LI, In=100A overload protection Ir=40A...100A short-circuit protection Ii=1.5...12 x In clamp connection undervoltage release (UVR) 24V DC 2 auxi |  | 
											
						
							| 3VA2110-5HL36-0BL0 | Siemens | circuit breaker 3VA2 IEC frame 160 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU320, LI, In=100A overload protection Ir=40A...100A short-circuit protection Ii=1.5...12 x In clamp connection undervoltage release (UVR) 24V DC 2 auxi |  |